Bathroom Electrical Zones Explained: Lights, Showers, Sockets and IP Ratings

Last reviewed November 2026

Bathrooms are treated as special locations in BS 7671 because water and electricity together increase the risk of electric shock. The area around a bath or shower is divided into zones, with zone 0 inside the bath or shower tray, zone 1 directly above it, and zone 2 around it. Each zone has rules about what equipment can be installed and what IP rating it needs. Electrical work in these zones is notifiable under Part P in England and should be carried out by a qualified, registered electrician.

This guide explains the zones and what they mean when you plan a new bathroom.

Zone 0

Zone 0 is the inside of the bath or shower tray. Only equipment specifically designed for use there, at extra low voltage and with a high level of water protection, is allowed. In practice very little is installed in zone 0.

Zone 1

Zone 1 is the space directly above the bath or shower tray, up to a set height above the floor. Equipment here must be suitable for the location and have an appropriate IP rating to resist water jets. Electric showers and suitable shower lights and fans are typical. Equipment must be designed and installed for this zone.

Zone 2

Zone 2 extends a set distance horizontally beyond the edge of the bath or shower and up to a set height. Equipment here also needs suitable water protection. Shaver supply units that meet the relevant standard can be installed in zone 2 when positioned to avoid direct spray.

Outside the zones

The rest of the room is outside the zones. Normal accessories can sometimes be used here, but the room is still damp and the regulations still apply. Standard 13A sockets are not allowed within a set distance of the edge of zone 1, which in most bathrooms rules them out.

IP ratings explained

IP stands for ingress protection. The rating has two numbers: the first for protection against solid objects, the second for water. For example, a light rated IPX4 resists splashing water from any direction, while a higher second number means more protection against jets or immersion. The required rating depends on the zone and conditions such as whether water jets are used for cleaning. Check product labels and ask your electrician which rating suits each position.

Lights and extractor fans

Bathroom lights and fans need the right IP rating for their zone. Many shower area downlights are designed to be fitted in zone 1. Extractor fans in zone 1 or 2 must be suitable for that zone and may need a fused spur with the isolator positioned outside the zones. If you are fitting downlights through a ceiling with rooms above, our fire rated downlights guide explains when fire rated fittings are needed.

Electric showers

Electric showers draw a large current and need a dedicated circuit of the right size, correct protection and a suitable isolating switch, usually a ceiling pull cord or a wall switch outside the zones. Replacing a shower with a more powerful model may need a new circuit. Our electric shower installation cost guide explains what affects the work.

RCD protection

BS 7671 requires circuits serving a bathroom to have RCD protection. If your consumer unit lacks RCDs, a new bathroom project can be a good time to consider an upgrade. See our consumer unit upgrade guide.

Supplementary bonding

Older bathrooms usually had supplementary bonding cables linking metal pipes and fittings. Under current rules this can be omitted in certain conditions, including RCD protection for all circuits in the room and adequate main bonding. An electrician will decide. Our earthing and bonding guide explains why bonding matters.

Underfloor heating and heated mirrors

Electric underfloor heating and heated mirrors need careful design, RCD protection and positioning appropriate to the zones. Include them in the plan from the start.

Part P and certificates

Work in the zones around a bath or shower is notifiable under Part P. A registered electrician will notify the work through their competent person scheme and give you a certificate. Our Part P and electrical certificates guide explains this further.

Planning a bathroom refit

  1. Decide where the bath, shower and basin will go first, because this sets the zones.
  2. Choose lights, fans and shaver points with suitable IP ratings.
  3. Plan isolation switches outside the zones.
  4. Check the shower circuit is suitable for the new unit.
  5. Coordinate with the plumber and tiler so cables are in place before finishes.

Shaver points and electric toothbrush chargers

Shaver supply units contain an isolating transformer and are designed for low power devices such as shavers and toothbrush chargers. They are not suitable for hair dryers or straighteners. Keep high powered appliances out of the bathroom, or use them outside the room.

Next steps

See our domestic electrical page for the work we carry out. If you are planning a bathroom refit, contact us for advice and a quotation.

Wet rooms

Wet rooms have no shower tray, so the zones are set by the position of the shower head and the layout of the room. This can bring more of the room into zone 1 or 2. Plan wet room electrics with your electrician early, so lights, fans and heating are positioned and rated correctly.

Common mistakes

Standard light fittings above showers, sockets too close to baths, extractor fans without suitable isolation and missing RCD protection are some of the most common bathroom faults found on EICRs. Using a qualified electrician from the start avoids costly changes after the room is tiled.

Frequently asked questions

What are bathroom zones?

BS 7671 divides the area around a bath or shower into zones 0, 1 and 2, each with rules about what equipment can be installed and what IP rating it needs.

Can I have a plug socket in a bathroom?

Standard 13A sockets must be kept a set distance from the bath or shower, which rules them out in most bathrooms. Shaver supply units are commonly used instead.

What IP rating do bathroom lights need?

It depends on the zone. Lights in zones 1 and 2 need a suitable rating against water, often at least IPX4. Your electrician will advise for each position.

Is bathroom electrical work notifiable?

Work in the zones around a bath or shower is notifiable under Part P in England and should be carried out by a registered electrician.

Do bathrooms still need bonding?

Supplementary bonding can be omitted when certain conditions are met, including RCD protection and adequate main bonding.